Thermocouple Cable
Thermocouple Cable

MULTIPAIR THERMOCOUPLE

not armoured

  • XLPE/IS/OS/LSZH

armoured

  • XLPE/IS/OS/LSZH/SWA/LSZH

 

Applications

Can be used in cable tray or conduit to connect different types of thermocouple in industrial process controls, refineries, oil and gas plants.

Temperature range

-20 °C to +80 °C (for general use);
-40 °C to +90 °C (on request).

Minimum bending radius

Not armoured type:
12 times the outer diameter (for conductors class 1 and class 2);
10 times the outer diameter (for conductors class 5).
Armoured type:
15 times the outer diameter.

Applicable Standards

BS 5308 or
EN 50288-7
Basic design
IEC 60332-1 Flame retardant
IEC 60332-3 Fire retardant (cat. C or A according to requirements)
IEC 60754-1 Halogen free properties (only for LSZH cables)
IEC 61034-2 Low smoke emission (only for LSZH cables)

Available on request

Calibration and colours according to BS – DIN – NF – UNI.
Stranded conductors.
Galvanized steel wire braid (GSWB) or galvanized steel tape armour (GSTA).
Sheath materials can be provided for excellent water, oil, hydrocarbons, UV resistance or other special performance.

Cable construction

Conductors

Solid alloy.

Calibration

ANSI MC 96.1 or IEC 60584-3.

Insulation

PVC, PE, XLPE or LSZH thermoplastic material.

Twisting

The insulated cores shall be twisted in pairs/triads for a good reduction of the electromagnetic noise.

Individual screen

Aluminium/polyester tape, coverage >100%, aluminium in contact with tinned copper drain wire.

Cabling

The screened pairs are cabled with suitable non hygroscopic fillers (when necessary) and wrapped with polyester tape if required.

Overall screen

Aluminium/polyester tape, coverage >100%, aluminium in contact with tinned copper drain wire.

Inner sheath

PE, PVC or LSZH thermoplastic material.

Armour

Single layer of galvanized steel wires (SWA).

Outer sheath

PVC or LSZH thermoplastic material.
Enquiry Form

Fibre Optic Cable
Fibre Optic Cable

 

SIMPLEX/DUPLEX

Simplex

Micro Simplex
MIC-000-01-M1

Simplex
SIM-000-01-M1

Duplex

Duplex Zip-Cord
DUP-000-02-M1

Duplex Double Sheath
DDG-000-02-M1

Applications

These cables are used to realize patch cords, equipment harnesses and internal connections.
They are compatible with all standard connectors.

Temperature range

-20 °C / + 80 °C (operating)
-30 °C / + 80 °C (storage)
-5 °C / + 60 °C (installation)

Minimum bending radius

20 times overall diameter (dynamic)
10 times overall diameter (static)

Applicable Standards

IEC 60793-1 Optical fibre characteristics
IEC 60794-1 Optical fibre cable characteristics
IEC 60332-3
EN 50266
Fire retardant
IEC 60332-1
EN 60332-1
Flame retardant
IEC 60754
EN 50267-2
Test on gases evolved during
combustion
IEC 61034-2
EN 50268-2
Low smoke emission

Available upon request

  • In case of use of semi-tight fibres, the code becomes:
    SIM(S) – DUP(S) – DDG(S)
  • Dimensions different from the standard
  • Different materials for the sheath:
    • PVC
    • Polyurethane
  • Colours upon request

Cable construction

Fibres

Singlemode and multimode fibres, with tight or semi-tight (S) coating.

Structure

  • In SIM and SIM(S) cables, the coated fibre is protected by a reinforcement layer made of aramidic yarns and by a LSZH (M1) sheath.
  • In MIC cable, the bare fibre is protected by a reinforcement layer made of aramidic yarns and by a LSZH (M1) sheath with a very small diameter (0,9 mm). It is suitable for applications where the space is limited.
  • The DUP cable is formed by two singlefibre SIM placed side by side, easily separable and suitable for direct connector installation.
  • The DDG cable is formed by two singlefibre SIM placed side by side and protected with LSZH (M1) sheath having an oval section to grant a higher mechanical protection.

Enquiry Form