Operating temperature
-40 °C to +90 °C

Minimum bending radius
Not armoured type:
12 times the outer diameter.
Armoured type:
15 times the outer diameter.

Applicable Standards
EN 50288-7 Basic design
IEC 60331-23 Fire resistant
IEC 60332-1 Flame retardant
IEC 60332-3 Fire retardant (cat. C or A according to requirements)
IEC 60754-1 Halogen free properties
IEC 61034-2 Low smoke emission

Cable construction
Conductors
Plain annealed electrolytic copper wire according to EN
60228 class 2 (R) stranded.

Insulation
Mica/Glass tape plus XLPE.

Twisting
The insulated cores shall be twisted in pairs for a good
reduction of the electromagnetic noise.

Cabling
The pairs are cabled with suitable non hygroscopic
fillers (when necessary) and wrapped with polyester tape
if required.

Overall screen
Aluminium/polyester tape, coverage >100%, aluminium in
contact with tinned copper drain wire.

Armoured
Inner sheath: PE, PVC or LSZH thermoplastic material.
Armour: Single layer of galvanized steel wires (SWA).

Outer sheath
LSZH thermoplastic material.